以文本方式查看主题 - 国际泵阀采购论坛-泵水泵油泵螺杆泵液下泵离心泵阀阀门采购阀门销售泵阀论坛 (http://www.pvwww.com/pvbbs/index.asp) -- English Only (http://www.pvwww.com/pvbbs/list.asp?boardid=14) ---- Redundancy, Redundancy: Reliability at an Influent Pump Station (http://www.pvwww.com/pvbbs/dispbbs.asp?boardid=14&id=5398) |
-- 作者:湖南水泵厂 -- 发布时间:2007/7/5 16:30:35 -- Redundancy, Redundancy: Reliability at an Influent Pump Station Redundancy, Redundancy: Reliability at an Influent Pump Station Located in northern Alabama and sited on the north bank of the Tennessee River, the Cypress Creek Wastewater Treatment Plant, named for the creek that forms the site\'s eastern border, serves the picturesque town of Florence and its population of approximately 17,000. The current plant went on-line in 2000, with the influent pump station going on-line in 1999, ahead of the main portion of the plant. Municipal Consultants, Inc. (Birmingham, AL) handled consulting engineering on the project, and Brasfield & Gorrie (Birmingham, AL) was the prime contractor. The plant\'s rated design capacity is 20-mgd, and it actually averages about 15-mgd. The entire plant is built above the 1,000-year flood level. Discharge from the plant goes into the Tennessee River through a diffuser located at a depth of approximately 20-ft, and the quality of the discharge is carefully monitored and controlled because of a federally-protected mussel area located downstream from the plant. The pump station building is physically and electrically divided into North and South. Two sewer lines, each serving different sections of the city, deliver wastewater to the pump station. Separate 50-ft deep wet wells can operate independently or, with a sluice gate between them raised, as a single unit. Separate utility power feeds to the plant are part of the redundancy plan. Another easy-to-overlook aspect of the plant\'s redundancy, especially for the influent pump station, is the attention to cooling. Large fans are located high on the pump building\'s end walls to provide cooling air movement in the event the building\'s air conditioning system fails. Each dry well houses three Patterson pumps, each with a capacity of 6,940-gpm. Facilities were designed to accommodate the addition of two pumps per dry well, giving the station an ultimate capacity of ten pumps. The final key to having full redundancy, and the most complex piece to achieve, lies with the pump control systems, designed and produced by Revere Control Systems (Birmingham, AL). As with the pumps themselves, the controls are divided into North and South segments. Each lineup of drives is controlled with an Allen-Bradley SLC 504 PLC. Ultrasonic level sensors in the wet wells provide the water level signals, and in keeping with the redundancy requirements, there are backup float level sensors. In the event that one of the PLCs fails, the PLC for the other lineup, following a five-second delay, is instructed to take control of both lineups. This redundant control extends to the HMI screen as well, allowing full control of both lineups from a single screen. To our knowledge, this was at the time the first such redundant application of the SLC 504 in the country, making the design and programming particularly challenging for the control systems company. We have now completed nearly seven years of operation with the influent pump station. Both the pumps and the controls have performed wonderfully for that period. During those seven years we have had no catastrophic failures and only one PLC failure. When that happened, the redundant design functioned exactly as planned, and we were able to operate the entire pump station on a single PLC until the failed unit could be replaced. The influent pumping station is the most critical component of the treatment facility. If this station isn\'t operating, the rest of the plant is useless. By making redundancy a foundational element of the pumping station\'s design in every aspect of the station, we have assured that this critical component is always functional, thus keeping the rest of the plant functional. |
-- 作者:7月7日雨 -- 发布时间:2007/8/4 22:03:03 -- It seems nice. Good guy!~ |
-- 作者:airfish -- 发布时间:2007/8/13 13:50:31 -- welcome |